Expanded_Serial_Command_Codes

Expand Serial Command Functional Specification Page 27 of 41
8.11.18. CF_LOGOCAPTURE Command
Command “CF_LOGOCAPTURE_%1” [CR]
%1 “START” ------------ Capture On
Details
Capture the current image on screen.
When beginning to capture the image, any command is not available until the
capture has done. When sending the command during the process, the Projector
returns the error code, “301”.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.11.19. CF_FANMODE Command
Command “CF_FANMODE_%1” [CR]
%1
“L1” -------- Select Fan mode L1
“L2” -------- Select Fan mode L2
Details
Select Fan mode. (Only valid when it is in the usual Power On status)
When select “L1”, more fan noise at power off.
When select “L2”, go quiet fan noise at power off. However, Fan movement is
more time than “L1”.
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]