Expanded_Serial_Command_Codes
Expand Serial Command Functional Specification Page 25 of 41
8.11.9. CF_P-MANE Command
Command “CF_P-MANE_%1” [CR]
%1
“OFF” --------------- Set Power Management to Off
“READY” ----------- Set Power Management to Ready
“SHUTDOWN” ---- Set Power Management to Shut Down
Details
Set / Cancel Power management. (Only valid when it is in the usual Power On
status)
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.11.10. CF_P-MANETIME Command
Command “CF_P-MANETIME_%1” [CR]
%1
“01” – “30” --------- Directly set the time by the minute
“UP” ----------------- Set the time 1 minute longer
“DN” ----------------- Set the time 1 minute shorter
Details
Set Power Management time. (Only valid when it is in the usual Power On
status)
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.11.11 CF_FANSPEED Command
Command “CF_FANSPEED_%1” [CR]
%1
“MAX” --------- Select Maximum speed
“NOR” ---------- Select Normal speed
Details
Change Fan Control speed. (Only valid when it is in the usual Power On status)
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.11.12. CF_KEYDIS Command
Command “CF_KEYDIS_%1” [CR]
%1
“NONE” ---------- RC and KEY are available
“RC” --------------- Key lock RC
“KEY” ------------- Key lock Unit
Details Set Key lock the RC / KEY. (Only valid when it is in the usual Power On status)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.11.13. CF_TERMINAL Command
Command “CF_TERMINAL_%1” [CR]
%1
“COMPUTER” -------- Set Input mode
“MONITOR” ----------- Set Monitor Output
Details
Set Terminal. (Only valid when it is in the usual Power On status)
In this model, Terminal is COMPTUER2.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]