Expanded_Serial_Command_Codes
Expand Serial Command Functional Specification Page 23 of 41
8.10.2. CF_MUTE Command
Command “CF_MUTE_%1” [CR]
%1
“ON” --------- Sound Mute On
“OFF” ------- Sound Mute Off
Details Control Sound Mute On/Off. (Only valid when it is in the usual Power On status)
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.11. Setting Command
8.11.1. CF_BBACK Command
Command “CF_BBACK_%1” [CR]
%1
“ON” --------- Set Blue Back
“OFF” ------- Cancel Blue Back
Details
Set / Cancel Blue Back. (Only valid when it is in the usual Power On status)
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.11.2. CF_DISP Command
Command “CF_DISP_%1” [CR]
%1
“ON” --------- Set Display
“OFF” ------- Cancel Display
Details
Set / Cancel Display. (Only valid when it is in the usual Power On status)
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable “000” [CR]
Response
Unacceptable Error Code” [CR]
8.11.3. CF_LOGO Command
Command “CF_LOGO_%1” [CR]
%1
“OFF” ------------------ Cancel Logo
“DEFAULT” ---------- Set Default Logo display
“USER” ---------------- Set Captured Logo display
Details
Set / Cancel Logo. (Only valid when it is in the usual Power On status)
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.11.4. CF_CEIL Command
Command “CF_CEIL_%1” [CR]
%1
“ON” ---------- Select Ceiling
“OFF” -------- Cancel Ceiling
Details
Set / Cancel Ceiling. (Only valid when it is in the usual Power On status)
This setting status is stored in EEPROM, hold even if AC Power turning Off and
On.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]