Expanded_Serial_Command_Codes

Expand Serial Command Functional Specification Page 13 of 41
8.4.5. CF_SHARP Command
Command “CF_SHARP_%1” [CR]
%1
“000 – 015” ------------ Directly select the Sharpness setting value
“UP” --------------------- Sharpness setting value +1
“DN” --------------------- Sharpness setting value -1
Details
Set the user control Sharpness value.
The value set by the command will not be saved to the Projector. Therefore, when
AC Power Off the Projector, the value will return to the original setting. (For
Standby mode, this value stays)
Only valid when it is in the usual Power On state.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.4.6. CF_GAMMA Command
Command “CF_GAMMA_%1” [CR]
%1
“000 – 015” ------------ Directly select the Gamma setting value
“UP” --------------------- Gamma setting value +1
“DN” --------------------- Gamma setting value -1
Details
Set the user control Gamma value.
The value set by the command will not be saved to the Projector. Therefore, when
AC Power Off the Projector, the value will return to the original setting. (For
Standby mode, this value stays)
Only valid when it is in the usual Power On state.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.4.7. CF_WBAL- Command
Command “CF_WBAL-%1_%2” [CR]
%1
“R” -------------------- Red
“G” -------------------- Green
“B” -------------------- Blue
%2
“000 – 063 ------- Directly select color value by White Balance %1 determination
“UP” ---------------- Color value for White Balance %1 determination +1
“DN” ---------------- Color value for White Balance %1 determination -1
Details
Set the user control value by White Balance %1 determination.
The value set by the command will not be saved to the Projector. Therefore, when
AC Power Off the Projector, the value will return to the original setting. (For
Standby mode, this value stays)
Only valid when it is in the usual Power On state.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]
8.4.8. CF_COLTEMP Command
Command “CF_COLTEMP_%1” [CR]
%1
“000” ----------- Xlow
“001” ----------- Low
“002” ----------- Mid
“003” ----------- High
Details
Set the Color Temp.
The value set by the command will not be saved to the Projector. Therefore, when
AC Power Off the Projector, the value will return to the original setting. (For
Standby mode, this value stays)
Only valid when it is in the usual Power On state.
Acceptable “000” [CR]
Response
Unacceptable “Error Code” [CR]