lv7210_series_basic_cmd
Basic Serial Functional Specification for LV-5210/7215/7210
7.3.9 “24” [CR]
Status: Processing Power Save・Cooling Down
Cooling down by the power management function in the e setting menu.
The control command is invalid.
This Power Save・Cooling Down moves to Power Save after the cooling down time.
Status: No signal POWER SAVE ・ COOLING DOWN
POWER SAVE
Response: ”00” “24” “04”
After 5 minutes with no signal after about 90 seconds
7.3.10 “04” [CR]
Status of Power Save
The status is Power Save by the Power management function in setting menu.
7.4 Input Mode Read COMMAND
COMMAND “CR1” [CR]
Detail Get selected Input No.
Acceptable
“%1” [CR]
%1
“1” = Computer1 is selected
“2” = Computer2 is selected
“3” = Video is selected.
Response
Unacceptable “?” [CR]
7.5 Lamp Time Read COMMAND
COMMAND “CR3” [CR]
Detail Get total lamp running hours.
Acceptable
“%1” [CR]
%1
Show as 4 digits
Ex.: “0410”[CR] ・・・・410 hours
Response
Unacceptable “?” [CR]
Page 21