Service manual

Chapter 2
2-6
F-2-10
3) Open the packaging bag of the new drum unit, take the new drum out of
it, and then remove packing tape.
The drum unit for Asia/Oceania is provided with pressure release hooks [1].
Remove them. Drum units for other regions are not provided with the pres-
sure release hooks.
F-2-11
4) Holding the protective cover [1] of the new drum unit, place the drum unit
against the iR body.
F-2-12
5) While holding the protective cover, insert the new drum unit [1] into the
iR body.
MEMO:
The protective cover will not be reused.
F-2-13
6) Turn the developer pressure release lever [1] counterclockwise, and then
close the left door [2].
F-2-14
7) Enter the date in the drum counter label [1].
F-2-15
8) Affix the drum counter label [1] on the drum unit.
F-2-16
9) Close the front cover [1].
F-2-17
[2]
[1]
[1]
[1]
[1]
[1]
[2]
[1]
[1]
[1]