Service manual

Chapter 16
16-1
16.1 Service Tools
16.1.1 Special Tools
0011-2844
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
In addition to the standard tools set, you will need the following special tools for servicing of the machine:
T-16-1
Key to Notation (rank)
A: each service engineer is expected to carry one.
B: each group of 5 service engineers is expected to carry one.
C: each workshop is expected to carry one.
16.1.2 Oils and Solvents
0011-2845
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
T-16-2
Tool name Tool No. Rank Shape Uses
Digital multimeter FY9-2002 A For making electrical
checks.
Cover switch TKN-0093 A
Tester extension pin FY9-3038 A As an addition when
making an electrical
check.
Tester extension pin (L-
shipped)
FY9-3039 A As an addition when
making an electrical
check.
NA-3 Test Chart FY9-9196 A For checking and
adjusting images.
Name Uses Composition Remarks
Alcohol cleaning; e.g.,
glass, plastic,
rubber; external
covers
fluoride-family hydrocarbon
alcohol
surface activating agent
water
- Do not bring near fire.
- Procure locally.
- IPA (isopropyl alcohol) may be
substituted.
Solvent cleaning; e.g.,
metal; soiling with
oil or toner
fluorine-family hydrocarbon
chlorine-family hydrocarbon
alcohol
- Do not bring near fire.
- Procure locally.
- MEK may be substituted.
Lubricant mineral oil (paraffin family) - CK-0524 (100 cc)
Lubricant drive mechanism,
sliding
mechanism,
scanner rail
silicone oil - CK-0551 (20 g)
Lubricant
(EM-50L)
gear special oil
special solid lubricating agent
lithium soap
- HY9-0007