Service manual

Chapter 14
14-16
Use it to set the CNG detention level for a fax/tel switchover.
14.5.12 <024: pseudo RBT transmission level at time of fax/tel switchover>
0011-1799
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set the pseudo transmission level for a fax/tel switchover.
14.5.13 <025: Answering machine connection function signal detection time>
0011-1800
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Sets the signal detection time for the answering machine connection function operation. When the answering machine connection function is operating, if the func-
tion does not operate normally because the fax does not detect CNG signal sent from the line, raise this parameter to increase the signal detection time.
14.5.14 <027: V.21 low-speed flag preamble identification length>
0011-1801
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to detect the time of detection after which command analysis is started after detecting V.21 low-speed command preambles continuously for a specific period
of time.
14.5.15 <056 - 061: Count type select >
0011-1858
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to confirm the count type indicated on the Counter Check screen, which appears in response to a press on the Counter key.
When '0' is selected, count type will not be indicated.
No.56: Use it to indicate the type of software counter 1 of the control panel. The type of soft counter 1 cannot be changed.
No.57: Use it to change the type of soft counter 2* of the control panel to suit the needs of the user.
No.58: Use it to change the type of soft counter 3* of the control panel to suit the needs of the user.
No.59: Use it to change the type of soft counter 4* of the control panel to suit the needs of the user.
No.60: Use it to change the type of soft counter 5* of the control panel to suit the needs of the user.
No.61: Use it to change the type of soft counter 6* of the control panel to suit the needs of the user.
*:The default type settings of soft counter is different from models.
<Soft Counter Specifications>
The soft counters are classified a follows in terms of input numbers:
100s: total
200s: copy
300s: print
400s: copy + print
500s: scan
700s: received file print
800s: report pint
900s: transmitted scan
Guide to the Table
- 1:Count sheets of all sizes by one.
- 2:Count sheets of the large size by two.
- C:full color
- Bk:black mono
- L:large size (larger than A4/LTR)
- S:small size (A4/LTR or smaller)
MEMO:
To make a change so that B4 papers (for print) will be counted as large-size, use service mode: make the following selections, and change bit 0 to '1': #SSSW>SW33.
To make a change so that B4 papers (for scan) will be counted as large-size, use service mode: make the following selections, and change bit 2 to '1': #SSSW>SW33.
Seri
al
No.
on
cou
nter
chec
k
scre
en
Counter type Print system
Bk 1-sided L Bk 1-sided S Bk 2-sided L Bk 2-sided S
Local
copy
PDL
print
FAX
print
Repo
rt
print
Local
copy
PDL
print
FAX
print
Repo
rt
print
Local
copy
PDL
print
FAX
print
Repo
rt
print
Local
copy
PDL
print
FAX
print
Repo
rt
print
101Total1 11111111
102Total2 22221111
103 Total (L) 1 1 1 1
104Total (S) 1111
108Total (Bk1) 11111111
109Total (Bk2) 22221111
112 Total (Bk/L) 1 1 1 1
113Total (Bk/S) 1111
114Total1 (2-sided) 11111111
115Total2 (2-sided) 22221111
116 L (2-sided) 1111
117 S (2-sided) 1111
126 TotalA1 1 1 1 1 1 1
127 TotalA2 2 2 2 1 1 1
128 TotalA (L) 1 1 1
129 TotalA (S) 1 1 1
132 TotalA (Bk1) 1 1 1 1 1 1