Service manual

Chapter 14
14-14
##103, ##107, ##114, ##201, ##790, ##793
14.4.3 <No.006 telephone line monitor>
0011-1771
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to s the telephone line monitor function:
DIAL: generate the monitor sound of the telephone line using the speaker from the start of transmission to DIS.
SERVICEMAN [1]: generate the monitor sound of the telephone line using the speaker from the start of communication to the end of it.
SERVICEMAN [2]: generate the monitor sound of the telephone line2 (Option).
OFF: do not generate the monitor sound of the telephone line using the speaker.
14.4.4 <No.007 ATT transmission level>
0011-1772
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set the transmission level (ATT).
Raise the transmission level if errors occur frequently at time of communication because of the condition of the line. (It means close to 8)
Any of the following error codes may be indicated at time of transmission because of the line condition:
##100, ##101, ##102, ##104, ##201, ##280, ##281, ##282, ##283, ##284, ##750, ##752, ##754, ##755, ##757, ##759, ##760, ##762, ##764, ##765,
##767, ##769, ##770, ##772, ##774, ##775, ##777, ##779, ##780, ##782, ##784, ##785, ##787, ##789
Any of the following error codes may be indicated at time of reception because of the line condition:
##103, ##106, ##107, ##201, ##793
14.4.5 <No.008 V.34 modulation speed upper limit>
0011-1773
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set an upper limit to the modulation speed (baud rate) for the V.34 primary channel.
14.4.6 <No.009 V.34 data speed upper limit>
0011-1774
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to set an upper limit to the data transmission speed for the V.34 primary channel between 2.4K and 33.6K bps in increments of 2400 bps. (0: 2.4K to 13:
33.6K bps).
14.4.7 <No.010 Frequency of the pseudo CI signal>
0011-1775
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
You may select a frequency for the pseudo CI signal.
Some types of external telephones do not ring when the fax/tel switch-over function is ON. To sound the ring, change the pseudo CI signal.
14.5 Setting of Numeric Parameter (NUMERIC Param.)
14.5.1 Numerical Parameter Composition
0011-1777
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
T-14-16
No. Item Range of settings
002 RTN transmission condition(1) 1% to 99%
003 RTN transmission condition (2) 2 to 99 item
004 RTN transmission condition (3) 1 to 99 lines
005 NCC pause time length (pre-ID code) 1 to 60 sec
006 NCC pause time length (post-ID code) 1 to 60 sec
010 line condition identification time length 0 to 9999 (10 msec)
011 T.30T1 timer (for reception) 0 to 9999 (10 msec)
013 T.30 EOL timer 500 to 3000 (10 msec)
015 hooking detection time length 0 to 999
016 time length to first response at time of fax/tel switchover 0 to 9
017 pseudo RBT signal pattern ON time length 0 to 999
018 pseudo RBT signal pattern OFF time length 0 to 999
(short)
019 pseudo RBT signal pattern OFF time length 0 to 999
(long)
020 pseudo CI signal pattern ON time length 0 to 999
021 pseudo CI signal pattern OFF time length 0 to 999
(short)
022 pseudo CI signal pattern OFF time length (long) 0 to 999
023 CNG detection level at time of fax/tel switchover 0 to 7
024 pseudo RBT transmission level at time of fax/tel switchover 10 to 20
0 to 20 (120/230V)
025 Answering machine connection function signal detection
time
0 to 999
027 preamble detection time length for V21 low-speed flag 20 (x 10ms)
056 display the type of soft counter 1 101 (Fixed)