Service manual
Chapter 14
14-13
If 'yes' is selected, the serial No. will be indicated.
If 'no' is selected, on the other hand, the serial No. will not be indicated.
14.3.11.4 Detailed Discussions of Bit 2
0011-1764
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to specify whether B4 paper (Scan) should be counted as large-size paper.
If 'yes' is selected, B4 paper will be counted as large-size paper.
If 'no' is selected, on the other hand, B4 paper will be counted as small-size paper.
14.3.11.5 Detailed Discussions of Bit 3
0011-1765
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Select whether to switch the counter display type in effect in Japan to the conventional or new type. Select "Yes" to display counters in the new type. Select "No"
to display counters in the conventional type.
14.3.12 SSSW-SW34
14.3.12.1 List of Functions
0011-1766
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
T-14-14
The default setting of this SSSW varies depending on the destination of the product.
Product for Japan: 00000000
Product for countries in Euro zone: 00000011
Products for other countries/regions: 00000001
14.3.12.2 Detailed Discussions of Bit 0
0011-3594
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
You can select whether a waste toner full warning is to be displayed.
When "1" is selected, a waste toner full warning is displayed.
When "0" is selected, a waste toner full warning is not displayed.
14.3.12.3 Detailed Discussions of Bit 1
0011-1767
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Select whether to display the waste toner full warning as a drum replacement required message or as E019 displayed on an operator call. Select 1 to display a rum
replacement required message on an operator call. Select 0 to display E019 on an service call.
14.4 Setting of Menu Switch (Menu)
14.4.1 Menu Switch Composition
0011-1768
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
T-14-15
14.4.2 <No.005 NL equalizer>
0011-1770
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
Use it to enable-disable the NL equalizer.
If errors occur often during communication because of the condition of the line, enable (ON) the NL equalizer.
Any of the following error codes may be indicated at time of transmission because of the line condition:
##100, ##101, ##102, ##104, ##201, ##281, ##282, ##283, ##750, ##755, ##765, ##774, ##779, ##784, ##789
Any of the following error codes may be indicated at time of transmission because of the line condition:
Bit Function 1 0
0 Display the waste toner full
warning
YES NO
1 Switch the waste toner full
warning
Drum replacement required
message displayed on an
operator call
E019 displayed on an service
call
2 Not used - -
3 Not used - -
4 Not used - -
5 Not used - -
6 Not used - -
7 Not used - -
No. Function Range of settings
005 NL equalizer 1: ON, 0: OFF
006 telephone line monitor 0:DIAL, 1:SERVICEMAN1, 2:SERVICEMAN2, 3:OFF
007 transmission level (ATT) from 0 to 15 (ex: 15= -15 dBm)
008 V.34 modulation speed upper
limit
0:3429, 1:3200, 2:3000, 3:2800, 4:2743, 5:2400
009 V34 data speed upper limit 0:33.6 kbps, 1:31.2 kbps, 2:28.8 kbps, 3:26.4 kbps, 4:24.0 kbps,
5:21.6 kbps, 6:19.2 kbps, 7:16.8 kbps, 8:14.4 kbps, 9:12.0 kbps,
10:9.6 kbps, 11:7.2 kbps, 12:4.8 kbps, 13:2.4 kbps
010 Frequency of pseudoring signal 0:50 Hz, 1:25 Hz, 2:17 Hz