Service manual

Chapter 14
14-3
F-14-2
14.2 Default settings
14.2.1 Service Mode Menus
0011-1722
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
#SSSW
No. Initial setting Function
SW01 0 error/copy control
SW02 not used
SW03 0 echo remedy setting
SW04 10000000 communication fault remedy setting
SW05 0 standard function (DIS signal) setting
SW06 - SW11 not used
SW12 10 page timer setting
SW13 0 meter/inch resolution setting
SW14 1 inch/meter resolution setting
SW15 - SW27 not used
SW28 0 V.8/V.34 protocol settings
SW29 not used
SW30 00000000(JPN)/
00000011(EURO)/
00000001(Other country/region)
Assigning a New Dial Tone Detection Method
SW31- SW32 not used
SW33 0 counter function settings
SW34 1 waste toner full display setting
SW35 - SW50 not used
1) Selecting Service Mode
Press the Additionalfunctions
key, 2key, 8key, Additional functions
key sequentially.
#SSSW
#NUMERIC Param.
#NUMERIC Param.
2) Selecting a Menu Item
Select the Menu item using the
[left arrow]/[right arrow] on the
touch panel.
3) Press [OK].
5) Registering/Setting Data
Enter data using the keypad,
and then press [OK].
6) Press the [Stop]/[Additional
functions]/[Reset] key to end
the service mode.
#NUMERIC Param.
# 3
NUMER I C Param.
001
001
002
002
0
0
10
4) Selecting a Prarameter
Select the Prarameter using the
[left arrow]/[right arrow].
1) Selecting Service Mode
Press the Additionalfunctions
key, 2key, 8key, Additional functions
key sequentially.
#SSSW
3) Selecting a Menu Item
Press [OK].
2) Press [OK] on the
touch panel.
5) Registering/Setting Data
Enter data using the keypad,
and press the [OK].
6) Press the [Stop]/[Additional
functions]/[Reset] key to end
the service mode.
033
4) Selecting a Bit Switch
Select the bit using the
[left arrow]/[right arrow] on
the touch panel.
#SSSW
#SSSW
000000000
000000000
<Operation at the time of Bit SW> <Operation at the time of Parameter>
033
#SSSW
000000000
033
#SSSW
000000001