Service manual

Chapter 4
4-1
4.1 Construction
4.1.1 Specifications, Control Methods, and Functions (iR2020/iR2020J/iR2020i)
0010-4242
iR2020 / / iR2020i
Major specifications, control methods, and functions of the original exposure system are summarized below.
T-4-1
4.1.2 Specifications, Control Methods, and Functions (iR2016/iR2016J/iR2016i)
0012-6043
iR2016J / iR2016 / iR2016i
Major specifications, control methods, and functions of the original exposure system are summarized below.
T-4-2
4.1.3 Major Components (iR2020/iR2020J/iR2020i)
0010-4243
iR2020 / / iR2020i
Major components of the original exposure system are as follows:
Item Function/Method
Exposure light source LED
Original scan In BOOK mode: Original scan is performed by moving the contact image sensor (CIS).
When ADF is used: Original stream reading is performed with the contact image sensor
(CIS) fixed.
Scan resolution 600 dpi (vertical scan) x 600 dpi (horizontal scan) (Color send: 300 dpi horizontal scan)
Gradation 256
Carriage position
detection
Contact image sensor (CIS) HP sensor (SR401)
Magnification range 50% to 200%
Vertical scan direction: Image processing is by image processor PCB
Horizontal scan direction:
BOOK mode:
Carriage movement speed change and image
processing by image processor PCB *1
ADF mode:
Original feed speed change and image processing by
image processor PCB *1
Lens Rod lens array
CMOS sensor Number of lines: 1
Number of pixels: Total 7488 (incl. 7176 effective pixels)
Maximum original scan width: 304 mm
CIS drive control Drive control by reader motor (M401)
Original size detection [1] BOOK mode:
Vertical scan direction: Detection by reflection type sensor (AB/INCH)
Horizontal scan direction: Detection by reflection type sensor (AB/INCH)
[2] When ADF is used
Width: Detection by original width sensor PCB in ADF
Length: Detection by photo sensor in ADF
*1 The control method depends on the magnification. For more details, refer to "Magnification Change".
Item Function/Method
Exposure light source LED
Original scan In BOOK mode: Original scan is performed by moving the contact image sensor (CIS).
When ADF is used: Original stream reading is performed with the contact image sensor
(CIS) fixed.
Scan resolution 600 dpi (vertical scan) x 600 dpi (horizontal scan) (Color send: 300 dpi horizontal scan)
Gradation 256
Carriage position
detection
Contact image sensor (CIS) HP sensor (SR401)
Magnification range 50% to 200%
Vertical scan direction: Image processing is by image processor PCB
Horizontal scan direction:
BOOK mode:
Carriage movement speed change and image
processing by image processor PCB *1
ADF mode:
Original feed speed change and image processing by
image processor PCB *1
Lens Rod lens array
CMOS sensor Number of lines: 1
Number of pixels: Total 7488 (incl. 7176 effective pixels)
Maximum original scan width: 304 mm
CIS drive control Drive control by reader motor (M401)
Original size detection [1] BOOK mode: not used
[2] When ADF is used
Width: Detection by original width sensor PCB in ADF
Length: Detection by photo sensor in ADF