Service manual

Chapter 3
3-11
F-3-29
6) Remove the 10 screws [1], and then detach the IP cover [2].
F-3-30
3.5.1.8 Removing the image processor PCB
0010-8719
iR2016J / iR2016 / iR2020 / / iR2016i / iR2020i
1) Remove six connectors [1].
F-3-31
2) Remove the five screws [1], and detach the image processor PCB [2].
F-3-32
3.5.1.9 Procedure after Replacing the Image Processor
PCB (iR2020/iR2020J/iR2016/iR2016J)
0011-3396
iR2016J / iR2016 / iR2020 /
If you have replaced the image processor PCB with a new one, perform the
following operations:
- Using the service support tool, download the latest firmware (System/
Boot).
- Input the all value printed on the service label affixed to the rear cover.
Make the following adjustments:
- Correction of output between CIS channels
1) Enter the service mode.
Sequentially press the User Mode key " ", 2 key, 8 key, and User Mode
key " " on the operation panel.
2) Using the arrow keys on the operation panel, display "TEST MODE".
3) Press the OK key.
4) Press the 2 key. "SCAN TEST" appears.
5) Press the 1 key.
After completion of the above steps, contact sensor output correction will be
performed and parameters will be set automatically.
- Read position adjustment (Stream reading: Only when the ADF is installed)
1) Enter the service mode.
Press the User Mode key " ", 2 key, 8 key, User Mode key " " on the
operation panel of the host machine.
2) Using the arrow keys on the operation panel, display "TEST MODE".
3) Press the OK key.
4) Press the 2 key. "SCAN TEST" appears.
5) Press the 3 key. "SHEET POS ADJ" appears.
The optical system starts scanning. Several seconds later, automatic adjust-
ment of the reading position finishes and "OK" appears.
If automatic adjustment fails, "NG" appears. Perform the following pro-
cedure:
Clean the white roller of the DADF and the document glass of the host ma-
chine, and then retry auto adjustment.
3.5.1.10 Procedure after Replacing the Image Processor
PCB (iR2020i/iR2016i)
0012-6052
iR2016i / iR2020i
If you have replaced the image processor PCB with a new one, perform the
following operations:
- Using the service support tool, download the latest firmware (System/Boot)
and language files.
- Delete the languages not used at the destination (Service mode > CLEAR
> FILE SYSTEM).
- Input the all value printed on the service label affixed to the rear cover.
Make the following adjustments:
- Correction of output between CIS channels
1) Enter the service mode.
Sequentially press the Additional functions key, 2 key, 8 key, and Additional
functions key on the operation panel.
2) Press the arrow key on the touch panel to display "TEST MODE".
3) Press [OK].
4) Press the [2] key to display "SCAN TEST".
5) Press the [1] key to display "SHADING".
6) Press [OK].
After completion of the above procedure, the contact sensor output is com-
pensated and parameters are set automatically.
[1]
[2]
[1]
[1]
[1]
[2]
[1] [1]
[1]
[1]
[
2]