14.3.6 <011: T.30 T1 timer (for reception)>
0011-4152
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Set the T1 timer for the receiver (wait time after DIS transmission starts until a significant signal is received).
14.3.7 <013: T.30 EOL timer>
0011-4153
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Set it so that the 1-line transmission time is longer for reception to prevent reception errors caused by a long data length per line (e.g., computer FAX).
14.3.8 <016: time length to first response at time of fax/tel switchover>
0011-4155
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Allows setting of the time from seizing the line till pseudo RBT is sent, when the Fax/ Tel switching function is operating.
14.3.9 <017: pseudo RBT signal pattern ON time length><018: pseudo RBT signal pattern OFF time length (short)><019:
pseudo RBT signal pattern OFF time length (long)>
0011-4156
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to set the pattern of the pseudo RBT signal transmitted at time of a fax/tel switchover.
14.3.10 <020: pseudo CI signal pattern ON time length><021: pseudo CI signal pattern OFF time length (short)><022:
pseudo CI signal pattern OFF time length (long)>
0011-4157
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to set the pseudo CI signal pattern transmitted at time of a fax/tel switchover.
14.3.11 <023: CNG detention level for fax/tel switchover>
0011-4158
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to set the CNG detention level for a fax/tel switchover.
14.3.12 <024: pseudo RBT transmission level at time of fax/tel switchover>
0011-4159
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to set the pseudo transmission level for a fax/tel switchover.
14.3.13 <025: Answering machine connection function signal detection time>
0011-4160
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Sets the signal detection time for the answering machine connection function operation. When the answering machine connection function is operating, if the func-
tion does not operate normally because the fax does not detect CNG signal sent from the line, raise this parameter to increase the signal detection time.
14.3.14 <027: V.21 low-speed flag preamble identification length>
0011-4161
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to detect the time of detection after which command analysis is started after detecting V.21 low-speed command preambles continuously for a specific period
of time.
14.4 Scanner Function Settings (SCANNER)
14.4.1 Numeric Parameter Functional configuration
0011-4164
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
No. Function Default Setting range Unit
001: - 023: Not used
024: CIS scan position during ADF scanning. 385 300-450 one unit=0.1mm
025: Not used
026: Distance from the standby position of CIS to the
shading start point.
22 6-48 one unit=0.1mm
027: - 030: Not used
031: Vertical scan start position adjustment 35 0-70 one unit=0.1mm
032: Horizontal scan start position adjustment 115 50-150 one unit=0.1mm
033: Vertical scan magnification correction 32 0-32 one unit=0.1%
034: Horizontal scan magnification correction 32 0-32 one unit=0.1%
035: - 036: Reader motor speed adjustment 555
037: - 040: Not used
041: Vertical scan start position adjustment (scanning
on ADF)
35 0-70 one unit=0.1mm
042: Horizontal scan start position adjustment
(scanning on ADF)
219 170-270 one unit=0.1mm
043: Horizontal scan end position correction
(copy:scanning on ADF)
75 0-200 one unit=0.1mm
044: Horizontal scan end position correction
(superfine:scanning on ADF)
75 0-200 one unit=0.1mm