14.1.9.2 Detailed Discussions of Bit 5
0011-4124
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
When "Detect with the new method" is selected, tone is detected for 3.5 seconds before call origination in order to discriminate between dial tone and voice. If dial
tone is detected and the time since line seizure is 3.5 seconds or longer, call origination takes place immediately. If the time since line seizure is less than 3.5 seconds,
call origination takes place after waiting for 1 second. (If the time since line seizure reaches 3.5 seconds during the 1-second waiting period, call origination takes
place immediately. By default, "Detect with a new method" is assigned for this SW.
14.2 Menu Switch Settings (MENU)
14.2.1 Menu Switch Composition
0011-4137
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
T-14-13
14.2.2 <No.005 NL equalizer>
0011-4138
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to enable-disable the NL equalizer.
If errors occur often during communication because of the condition of the line, enable (ON) the NL equalizer.
Any of the following error codes may be indicated at time of transmission because of the line condition:
##100, ##101, ##102, ##104, ##201, ##281, ##282, ##283, ##750, ##755, ##765, ##774, ##779, ##784, ##789
Any of the following error codes may be indicated at time of transmission because of the line condition:
##103, ##107, ##114, ##201, ##790, ##793
14.2.3 <No.006 telephone line monitor>
0011-4141
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to s the telephone line monitor function:
DIAL: generate the monitor sound of the telephone line using the speaker from the start of transmission to DIS.
SERVICEMAN [1]: generate the monitor sound of the telephone line using the speaker from the start of communication to the end of it.
SERVICEMAN [2]: generate the monitor sound of the telephone line2 (Option).
OFF: do not generate the monitor sound of the telephone line using the speaker.
14.2.4 <No.007 ATT transmission level>
0011-4142
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to set the transmission level (ATT).
Raise the transmission level if errors occur frequently at time of communication because of the condition of the line. (It means close to 8)
Any of the following error codes may be indicated at time of transmission because of the line condition:
##100, ##101, ##102, ##104, ##201, ##280, ##281, ##282, ##283, ##284, ##750, ##752, ##754, ##755, ##757, ##759, ##760, ##762, ##764, ##765,
##767, ##769, ##770, ##772, ##774, ##775, ##777, ##779, ##780, ##782, ##784, ##785, ##787, ##789
Any of the following error codes may be indicated at time of reception because of the line condition:
##103, ##106, ##107, ##201, ##793
14.2.5 <No.008 V.34 modulation speed upper limit>
0011-4143
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to set an upper limit to the modulation speed (baud rate) for the V.34 primary channel.
14.2.6 <No.009 V.34 data speed upper limit>
0011-4145
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to set an upper limit to the data transmission speed for the V.34 primary channel between 2.4K and 33.6K bps in increments of 2400 bps. (0: 2.4K to 13:
33.6K bps).
14.2.7 <No.010 Frequency of the pseudo CI signal>
0011-4146
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
You may select a frequency for the pseudo CI signal.
Some types of external telephones do not ring when the fax/tel switch-over function is ON. To sound the ring, change the pseudo CI signal.
7 Not used - -
No. Function Range of settings
005 NL equalizer 1: ON, 0: OFF
006 telephone line monitor 0:DIAL, 1:SERVICEMAN1, 2:SERVICEMAN2, 3:OFF
007 transmission level (ATT) from 0 to 15 (ex: 15= -15 dBm)
008 V.34 modulation speed upper
limit
0:3429, 1:3200, 2:3000, 3:2800, 4:2743, 5:2400
009 V34 data speed upper limit 0:33.6 kbps, 1:31.2 kbps, 2:28.8 kbps, 3:26.4 kbps, 4:24.0 kbps,
5:21.6 kbps, 6:19.2 kbps, 7:16.8 kbps, 8:14.4 kbps, 9:12.0 kbps,
10:9.6 kbps, 11:7.2 kbps, 12:4.8 kbps, 13:2.4 kbps
010 Frequency of pseudoring signal 0:50 Hz, 1:25 Hz, 2:17 Hz
Bit Function 1 0