14.1.7.2 Detailed Discussions of Bit 2
0011-4109
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to specify whether to convert or not convert an inch-configuration resolution into a millimeter-configuration resolution for image read in G3 transmission:
either in sub scanning direction only or in both main and sub scanning directions. The setting is valid only when bit 1 of SW05 of #SSSW is set to '1'.
14.1.7.3 Detailed Discussions of Bit 4
0011-4111
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to specify whether to declare or not declare an inch-configuration resolution to the other machine for G3 communication: if 'declare' is selected, the machine
will indicate that it reads and records at an inch-configuration resolution using the DIS, DCS, or DTC signal.
14.1.8 SSSW-SW28
14.1.8.1 List of Functions
0011-4112
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
T-14-11
14.1.8.2 Detailed Discussions of Bit 0
0011-4113
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Select whether to use the V.8 protocol when calling. If NO is selected, the V.8 protocol is inhibited at calling and the V.21 protocol is used.
14.1.8.3 Detailed Discussions of Bit 1
0011-4114
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Select whether to use the V.8 protocol when called. If NO is selected, the V8 protocol is inhibited when called and the V.21 protocol is used.
14.1.8.4 Detailed Discussions of Bit 2
0011-4115
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
If ANSam signal is not received during transmission, select whether to use the V.8 protocol when the other fax machine declares the V.8 protocol in DIS signal. If
NO is selected, the CI signal is not transmitted and the V.8 protocol is not used even if the DIS that specifies the V.8 protocol is received.
The V.8 late start is not executed during manual transmission regardless of this setting.
14.1.8.5 Detailed Discussions of Bit 3
0011-4116
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Select whether to declare the V.8 protocol in DIS signal for reception. If NO is selected, the V.8 protocol cannot be used because it is not declared in DIS signal.
The V.8 late start is not executed during manual reception regardless of this setting.
14.1.8.6 Detailed Discussions of Bit 4
0011-4117
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Select whether the receiver falls back during V.34 reception. If 'Prohibit' is selected, the receiver does not fall back.
14.1.8.7 Detailed Discussions of Bit 5
0011-4118
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Select whether the transmitter falls beck during V.34 transmission. If 'Prohibit' is selected, teh transmitter does not fall back.
14.1.9 SSSW-SW30
14.1.9.1 List of Functions
0011-4123
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
T-14-12
Bit Function 1 0
0 Caller V.8 protocol NO YES
1 Called party V.8 protocol NO YES
2 Caller V.8 protocol late start NO YES
3 Called party V.8 protocol late start NO YES
4 V.34 reception fallback Prohibited Not prohibited
5 V.34 transmission fallback Prohibited Not prohibited
6 not used - -
7 not used - -
Bit Function 1 0
0 Not used - -
1 Not used - -
2 Not used - -
3 Not used - -
4 Not used - -
5 New dial tone detection method Detect with the new
method.
Detect with the
existing method.
6 Not used - -