Service manual

Chapter 14
14-1
14.1 Service Soft Switch Settings (SSSW)
14.1.1 SSSW-SW01:
14.1.1.1 List of Functions
0011-4093
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
T-14-1
14.1.1.2 Detailed Discussions of Bit 0
0011-4094
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Selects whether or not service error codes are output.
When output is selected, service error codes is report.
14.1.2 SSSW-SW03
14.1.2.1 List of Functions
0011-4095
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
T-14-2
14.1.2.2 Detailed Discussions of Bit 7
0011-4096
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to enable/disable transmission of a 1080-Hz tonal signal before transmission of the CED signal.
Select 'transmit' if errors occur frequently because of an echo when reception is from overseas.
Memo:
Any of the following error code may be indicated because of an echo at time of reception
##0005, ##0101, ##0106, ##0107, ##0114, ##0200, ##0201, ##0790
14.1.3 SSSW-SW04
14.1.3.1 List of Functions
0011-4097
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
T-14-3
14.1.3.2 Detailed Discussions of Bit 2
0011-4098
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
Use it to select the number of last flag sequences for a protocol signal (transmission speed at 300 bps). Select '2' if the other party fails to receive the protocol signal
properly.
Memo:
Bit Function 1 0
0 service error code output not output
1 not used - -
2 not used - -
3 not used - -
4 not used - -
5 not used - -
6 not used - -
7 not used - -
Bit Function 1 0
0 not used - -
1 not used - -
2 not used - -
3 not used - -
4 not used - -
5 not used - -
6 not used - -
7 tonal signal before CED signal transmission transmit do not transmit
Bit Function 1 0
0 not used - -
1 not used - -
2 the number of final flag sequences of protocol signals 2 1
3 Reception mode after CFR signal transmission high speed high speed/low speed
4 the length of the period of ignoring low speed signals after
CFR output
1500 ms 700 ms
5 not used - -
6 CNG signal for manual transmission Not transmitted Transmitted
7 CED signal for manual reception Not transmitted Transmitted