Service manual

Chapter 13
13-4
##0764 [Tx] at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-
EOM.
##0765 [Tx] at time of ECM transmission, no meaningful signal is received after transmission of PPS-EOP, causing the procedural signal
to be transmitted more than specified.
##0767 [Tx] at time of ECM transmission, DCN is received after transmission of PPS-EOP.
##0768 [Tx] at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-EOP,
or T5 time-out (60 sec) has occurred.
##0769 [Tx] at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-EOP.
##0770 [Tx] at time of ECM transmission, no meaningful signal is received after transmission of EOR-NULL, causing the procedural
signal to be transmitted more than specified.
##0772 [Tx] at time of ECM transmission, DCN is received after transmission of EOR-NULL.
##0773 [Tx] at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of EOR-
NULL, or T5 time-out (60 sec) has occurred.
##0774 [Tx] at time of ECM transmission, ERR is received after transmission of EOR-NULL.
##0775 [Tx] at time of ECM transmission, no meaningful signal is received after transmission of EOR-MPS, causing the procedural
signal to be transmitted more than specified.
##0777 [Tx] at time of ECM transmission, DCN is received after transmission of EOR-MPS.
##0778 [Tx] at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission EOR-MPS,
or T5 time-out (60 sec) has occurred.
##0779 [Tx] at time of ECM transmission, ERR is received after transmission of EOR-MPS.
##0780 [Tx] at time of ECM transmission, no meaningful signal is received after transmission of EOR-EOM, causing the procedural
signal to be transmitted more than specified.
##0782 [Tx] at time of ECM transmission, DCN is received after transmission of EOR-EOM.
##0783 [Tx] at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of EOR-
EOM, or T5 time-out (60 sec) has occurred.
##0784 [Tx] at time of ECM transmission, ERR is received after transmission of EOR-EOM.
##0785 [Tx] at time of ECM transmission, no meaningful signal is received after transmission of EOR-EOP, causing the procedural
signal to be transmitted more than specified.
##0787 [Tx] at time of ECM transmission, DCN is received after transmission of EOR-EOP.
##0788 [Tx] at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of EOR-
EOP, or T5 time-out (60 sec) has occurred.
##0789 [Tx] at time of ECM transmission, ERR is received after transmission of EOR-EOP.
##0790 [Rx] at time of ECM reception, ERR is transmitted after transmission of EOR-Q.
##0791 [Tx/Rx] while ECM mode procedure is under way, a signal other than a meaningful signal is received.
##0792 [Rx] at time of ECM reception, PPS-NULL cannot be detected over partial page processing.
##0793 [Rx] at time of ECM reception, no effective frame is received while high-speed signal reception is under way, thus causing time-
out.
##0794 [Tx] at time of ECM reception, PPR with all 0s is received.
##0795 [Tx/Rx] a fault has occurred in code processing for communication.
No. Tx/Rx Description