Service manual
Chapter 13
13-3
13.3.3 Service Error Code
13.3.3.1 Service Error Code
0012-5782
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
T-13-5
#0018 [Tx/Rx] auto call initiation has failed.
#0037 [Rx] image memory overflow at time of reception has occurred.
#0059 [Tx] The number you dial and connected number (CSI) does not match.
#0995/0099 [Tx/Rx] a memory communication reservation has been cancelled.
No. Tx/Rx Description
##0100 [Tx] at time of transmission, the procedural signal has been transmitted more than specified.
##0101 [Tx/Rx] the modem speed does not match that of the other party.
##0102 [Tx] at time of transmission, fall-back cannot be used.
##0103 [Rx] at time of reception, EOL cannot be detected for 5 sec (15 sec if CBT).
##0104 [Tx] at time of transmission, RTN or PIN is received.
##0106 [Rx] at time of reception, the procedural signal is received for 6 sec while in wait for the signal.
##0107 [Rx] at time of reception, the transmitting party cannot use fall-back.
##0109 [Tx] at time of transmission, a signal other than DIS, DTC, FTT, CFR, or CRP is received, and the procedural signal has been
sent more than specified.
##0111 [Tx/Rx] memory error has occurred.
##0114 [Rx] at time of reception, RTN is transmitted.
##0200 [Rx] at time of reception, no image carrier is detected for 5 sec.
##0201 [Tx/Rx] DCN is received outside the normal parity procedure.
##0220 [Tx/Rx] system error (main program out of control) has occurred.
##0232 [Tx] encoding error has occurred.
##0237 [Rx] decoding error has occurred.
##0261 [Tx/Rx] system error has occurred.
##0280 [Tx] at time of transmission, the procedural signal has been transmitted more than specified.
##0281 [Tx] at time of transmission, the procedural signal has been transmitted more than specified.
##0282 [Tx] at time of transmission, the procedural signal has been transmitted more than specified.
##0283 [Tx] at time of transmission, the procedural signal has been transmitted more than specified.
##0284 [Tx] at time of transmission, DCN is received after transmission of TCF.
##0285 [Tx] at time of transmission, DCN is received after transmission of EOP.
##0286 [Tx] at time of transmission, DCN is received after transmission of EOM.
##0287 [Tx] at time of transmission DCN is received after transmission of MPS.
##0288 [Tx] after transmission of EOP, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
##0289 [Tx] after transmission of EOM, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
##0290 [Tx] after transmission of MPS, a signal other than PIN, PIP, MCF, RTP, or RTN has been received.
##0670 [Tx] at time of V.8 late start, the V.8 ability of DIS front the receiving party is expected to be detected, and the CI signal is
expected to be transmitted in response; however, the procedure fails to advance, and the line is released because of T1 time-
out.
##0671 [Rx] at time of V.8 arrival, procedure fails to move to phase 2 after detection of CM signal from caller, causing T1 time-out
and releasing line
##0672 [Tx] at time of V.34 transmission, a shift in procedure from phase 2 to phase 3 and thereafter stops, causing the machine to release
the line and suffer T1 timeout.
##0673 [Rx] at time of V.34 reception, a shift in procedure from phase 2 to phase 3 and thereafter stops, causing the machine to release
the line and suffer T1 timeout.
##0674 [Tx] at time of V.34 transmission, a shift in procedure from phase 3 and phase 4 to the control channel and thereafter stops,
causing the machine to release the line and suffer T1 timeout.
##0675 [Rx] at time of V.34 reception, a shift in procedure from phase 3 and phase 4 to the control channel and thereafter stops, causing
the machine to release the line and suffer T1 timeout.
##0750 [Tx] at time of ECM transmission, no meaningful signal is received after transmission of PPS-NULL, causing the procedural
signal to be transmitted more than specified.
##0752 [Tx] at time of ECM transmission, DCN is received after transmission of PPS-NULL.
##0753 [Tx] at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-
NULL, or T5 time-out (60 sec) has occurred.
##0754 [Tx] at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-
NULL.
##0755 [Tx] at time of ECM transmission, no meaningful signal is received after transmission of PPS-MPS, causing the procedural signal
to be transmitted more than specified.
##0757 [Tx] at time of ECM transmission, DCN is received after retransmission of PPS-MPS.
##0758 [Tx] at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS,
or T5 time-out (60 sec) has occurred.
##0759 [Tx] at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS.
##0760 [Tx] at time of ECM transmission, no meaningful signal is received after transmission of PPS-EOM, causing the procedural
signal to be transmitted more than specified.
##0762 [Tx] at time of ECM transmission, DCN is received after transmission of PPS-EOM.
##0763 [Tx] at time of ECM transmission, the procedural signal has been transmitted more than specified after transmission of PPS-MPS,
or T5 time-out (60 sec) has occurred.
No. Tx/Rx Description
Download Free Service Manual And Resetter Printer at http://printer1.blogspot.com