Service manual
Chapter 13
13-1
13.1 Error Code
13.1.1 List of Error Codes
0011-6947
LaserBase MF6530 / / LaserBase MF6540PL / LaserBase MF6550 / KaserBase MF6560PL / / LaserBase MF6580PL
T-13-1
Display
Code
Detail Code Main Cause/Symptom Countermeasure
E000 0000 Startup error
The temperature detected by the main or sub thermistor does
not rise to the specified value during startup control.
- Check the fixing film connector.
- Replace the fixing film unit.
- Replace the DC controller PCB.
E001 0000 Abnormally high temperature (detected by main thermistor)
The main thermistor detected an abnormally high temperature
(235 deg C) during temperature control.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
0001 Abnormally high temperature (detected by sub thermistor)
The sub thermistor detected an abnormally high temperature
(300 deg C) during temperature control.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
E002 0000 Low temperature during temperature control.
The target temperature is not reached during temperature
control.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
E003 0000 Abnormally low temperature (detected by main thermistor)
After the temperature detected by the main thermistor has
reached the specified value, it does not reach the specified
value during initial rotation.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
0001 Abnormally low temperature (detected by sub thermistor)
After the temperature detected by the sub thermistor has
reached the specified value, it does not reach the specified
value during initial rotation.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the DC controller PCB.
E010 0000 Main motor failure
The main motor is faulty. - Check the connector of the main motor.
- Replace the main motor.
- Replace the DC controller PCB.
E100 0000 BD detection PCB failure
The BD detection PCB is faulty. - Check the connector of the BD detection PCB.
- Replace the laser scanner unit.
- Replace the DC controller PCB.
E197 0000 Printer engine communication error
Erroneous communication between the DC controller PCB and
image processor PCB was detected.
- Check the connectors of the DC controller PCB and image
processor PCB.
- Replace the DC controller PCB for normal connection.
- Replace the image processor PCB.
E716 0000 Erroneous communication with optional cassette
Disconnection of the optional cassette was detected after
power-on, detection of normal connection to the optional
cassette, and start of communication.
- Check the connectors of the optional cassette PCB and DC
controller PCB.
- Replace the optional cassette PCB for normal connection.
- Replace the DC controller PCB.
E733 0000 Erroneous communication between controller and printer
Cannot communicate with the printer at startup. - Check the connectors of the DC controller PCB and image
processor PCB for normal connection.
- Check the power supply of the printer (Check whether
initialization is performed at startup).
- Replace the DC controller PCB or image processor PCB.
E736 0000 CCU communication error
The installed modem PCB is incompatible. - Check the connectors of the image processor PCB and modem.
- Replace the modem PCB.
- Replace the image processor PCB.
E739 0000 Erroneous communication between controller and network board
The installed network board is incompatible. - Check the connectors of the image processor PCB and LAN
PCB for normal connection.
- Replace the LAN PCB.
- Replace the image processor PCB.
E805 0000 Fan failure
The fan is faulty. - Check the fan connector.
- Replace the fan.
- Replace the DC controller PCB.
E808 0000 Fixing drive circuit failure
- The heater does not turn on.
- A fixing drive motor failure was detected.
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the fixing drive motor.
- Replace the DC controller PCB.
- Replace the power supply PCB.
Download Free Service Manual And Resetter Printer at http://printer1.blogspot.com