Transmission/reception time out interval
Time out interval when transmitting (no image mode setting)
Time out interval when transmitting (image mode AA)
Time out interval when receiving
Table 13-513
Bit
Time out interval
8 minutes
16 minutes
32 minutes
64 minutes
76543210
0*****00
0*****00
0*****10
0*****11
Bit
Time out interval
8 minutes
16 minutes
32 minutes
64 minutes
76543210
1*****00
1*****01
1*****10
1*****11
Bit
Time out interval
8 minutes
16 minutes
32 minutes
64 minutes
76543210
1***00**
1***01**
1***10**
1***11**
Bit
Time out interval
8 minutes
16 minutes
32 minutes
64 minutes
76543210
1*00****
1*01****
1*10****
1*11****