13-90
#1 SSSW-SW12: Page timer settings
Table 13-512
These switches can set the page timer. When transmission or reception takes more
than 32 minutes on this machine, communications are stopped. When the timer is set to
other than 32 minutes, refer to the following page and set the appropriate time.
When “do not set” is selected for Bit 7, the one page time out interval is controlled by
Bit 0 and Bit 0, regardless of the communication mode.
SW
No.
Bit
No.
Function
12
0
Page time out interval when transmitting (none
when set to image mode)
Bit setting
10
10
110
2
Page time out interval when transmitting (when
set to image mode and A4 document mode)
10
310
4
Page time out interval when receiving
10
510
6 Reserved
7
Separate transmission and reception page timer
settings
Set Do not set