Service manual

#1 SSSW-SW04 communications trouble remedy setting
Table 13-506
[Bit 1]
Select whether or not to check the CI signal frequency upon automatic reception.
If “check” is selected, the upper and lower limits of the CI signal frequency will be
checked when a transmission arrives. The fax will switch to automatic reception only
when both signals are within the standard range.
[Bit2]
You can select the number of final flag sequences for the protocol signal (transmission
speed is 300 bps).
When the procedure signal sent out by this unit is not properly received by the destina-
tion machine, set the number to 2.
COPYRIGHT
©
1999 CANON INC. CANON GP160 REV.0 FEB. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 13 TROUBLESHOOTING
13-83
SW
No.
Bit
No.
Function
04
0 Reserved
Bit setting
10
1 CI signal frequency check Check Do not check
2 Number of protocol signal’s final flag sequences 2 1
3 Reception mode after CFR signal transmission High-speed
High-speed
/ low-speed
4
Time for which low-speed signal is ignored after
CFR signal transmission
1500ms 700ms
5 CI signal frequency check when PBX is set Check Do not check
6 CNG signal at manual transmission Do not send Send
7 CED signal at manual reception Do not send Send
Error codes for errors which occur upon transmission
##100, ##280, ##281, ##282, ##283, ##750, ##754, ##755, ##758, ##759, ##760,
##763, ##764, ##765, ##768, ##769, ##770, ##773, ##775, ##778, ##780, ##783,
##785, ##788
MEMO: