Service manual

COPYRIGHT
©
1999 CANON INC. CANON GP160 REV.0 FEB. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 7 PICK-UP/FEEDING SYSTEM
7-28
11)Remove the 5 installation screws
[19], and remove the pick-up unit.
4. To remove the pick-up solenoid
1) Remove the 3 installation screws [1],
and then remove the pick-up drive
unit cover [2].
If the pressure lever roller [3] is
secured by tape, etc., before remov-
ing the drive unit cover, re-installation
of the drive unit cover will be made
easier.
2) Remove the installation screw and
then remove the pick-up solenoid.
Figure 7-710
Figure 7-711
[19]
[1]
[3] [2]