Specifications
COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON DADF-J1 REV.0 MAR.2001
CHAPTER 2 OPERATIONS AND TIMING
2-24
2.3.5 Pre-Last Original Detection
Pre-last original detection makes use of the pre-last original sensor (S8). Detection is ex-
ecuted on small-size originals only. The DADF is designed to send the second original to the
separation assembly after it has picked up the first original (small-side). At that time, if no
original covers the pre-last original sensor (S8), the dada will assume that no original will
follow, and communicates as such to the copier.
Small-size: A5, A4, B5, STMT, LTR
Large-size: A4R, B5R, B4, LTRR, LGL, 279.4x431.8 mm (11"x17")
F02-203-08
F02-203-08
1st original
Pre-last original sensor
(S8)
Separation assembly
2nd original