Specifications

COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON DADF-J1 REV.0 MAR.2001
CHAPTER 5 TROUBLESHOOTING
5-64
4.1.2 DIP Switch Functions
The DIP switch (SW1) on the ADF controller PCB provides the following functions ac-
cording to how it is set:
Function
Normal operation
Operation Check
Setting
Description
Normal Operation
Single-Sided Intermittent Feed
Press the push switch SW2 on the ADF controller
PCB; thereafter, each press on the push switch SW2
will send the original intermittently.
Double-Sided Intermittent Feed
Press the push switch SW2 on the ADF controller
PCB; thereafter, each press on the push switch SW2
will send the original intermittently.
Belt Motor (M2) Drive
Press the push switch SW2 on the ADF controller
PCB to start it; another press will stop it.
The operation will be as follows, executed automati-
cally: CW (700 -> 520 -> 260 -> 30 mm/sec) -> (700
-> 520 -> 260 -> 130 mm/sec).
Reversal Motor (M1) Drive
Press the push switch SW2 on the ADF controller
PCB to start it; another press will stop it.
The operation will be as follows, executed automati-
cally: CW (700 -> 520 -> 260 -> 130 mm/sec) ->
CCW (700 -> 520 -> 260 -> 130 mm/sec).
Delivery Motor (M5) Drive
Press the push switch SW2 on the ADF controller
PCB to start it; another press will stop it.
While in operation, each press on the push switch
SW3 changes the speed of motor rotation to 100
mm/sec (700 -> 100 mm/sec).
Pickup Motor (M3) Drive
Press the push switch (SW2) on the ADF controller
PCB; press SW3 to move up or SW4 to move down.
Another press on SW2 will stop it.
T05-401-01a