Specifications

COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON DADF-J1 REV.0 MAR.2001
CHAPTER 5 TROUBLESHOOTING
5-7
2) Open the upper cover, and loosen the
fixing screw on the registration roller
mounting plate; then, slide it up/down
to adjust the mounting angle of the reg-
istration roller.
If A>0, slide the mounting plate down.
If B>0, slide the mounting plate up.
F05-101-13
3) At the end of adjustment, tighten the
fixing screw of the registration roller
mounting plate.
4) Set the DIP switch (SW1) on the ADF
controller PCB back to its initial setting,
and mount the ADF controller cover.
b. Pickup from the Manual Feed Tray
1) Remove the screw, and detach the ADF
controller cover.
2) Set the DIP switch (SW1) on the ADF
controller PCB as follows.
F05-101-14
F05-101-15
Registration roller mounting plate
Screw
Upper cover
ADF controller cover
Screw