Specifications
COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON DADF-J1 REV.0 MAR.2001
CHAPTER 5 TROUBLESHOOTING
5-2
1.1.2 ADF Right Angle Adjustment
This adjustment is to adjust the right
angle made by the copier’s scanner and the
DADF’s original feed path.
1) Using an A4 or LTR sheet of copy pa-
per, prepare a test chart as shown.
F05-101-03
2) Place the test chart in the original tray,
and make a Direct copy in stream read-
ing mode.
Be sure to use stream reading
mode.
F05-101-04
Right angle
10mm 10mm
10mm 10mm
Test chart