Specifications
COPYRIGHT
©
1999 CANON INC. CANON SUPER G3 FAX BOARD-F1 REV.0 MAY 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
5-23
CHAPTER 5 ERROR CODE
##784 (transmission) ERR received after transmission of EOR-EOM
Cause Remedy
• The condition of the line is poor, and the other
device cannot receive image signals often.
• The other device malfunctioned because of an
echo.
1. Raise the transmission level of the modem using
parameter 07 of #2 MENU so that the other
device may receive image signals properly.
2. Adjust the NL equalizer using parameter 05 of
#2 MENU so that the other device may receive
image signals properly.
1. Provide measures against echoes by referring to
31 SSSW SW03.
2. Add a longer pause to the end of the telephone
number when registering under auto dial to pre-
vent responding to the first DIS from the other
device.
3. Press the Start key after hearing the first DIS
from the other device in manual ringing.
4. Request the other party to lower the transmission
level of the other device so that the other device
will not receive echoes.
##785 (transmission) excess procedure signal re-transmission after transmission of EOR-
EOP (acknowledge signal not received)
Cause Remedy
• The line condition is poor, and the other device
cannot receive EOR-EOM correctly.
• The Stop button is pressed during communica-
tion.
• Raise the transmission level of the modem using
parameter 07 of #2 MENU so that the other
device may receive EOR-EOP properly.
• Request the other party to raise the level of the
other device so that signals may be received
properly.
##787 (transmission) DCN received after transmission of ERO-EOP
Cause Remedy
• The condition of the line is poor, and the other
device cannot receive EOR-EOP properly.
• The Stop key was pressed during communica-
tion.
• Raise the transmission level of the modem using
parameter 07 of #2 MENU so that the other
device may receive EOR-EOP properly.
• Try re-transmission.