Specifications
COPYRIGHT
©
1999 CANON INC. CANON SUPER G3 FAX BOARD-F1 REV.0 MAY 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
5-15
CHAPTER 5 ERROR CODE
##674 (transmission) line released by T1 time-out (procedure fails to move to control channel
onward from phase 3 or phase 4 during V.34 transmission)
Cause Remedy
• The line of the receiving device broke in phase
3 or phase 4, or signals of the receiving device
cannot be detected.
• Prohibit the V.8/V.34 procedure of the caller
using bit 0 of SW28 of #1 SSSW.
Adjust the transmission level to between 0 and
-15 dBm.
##675 (reception) line released by T1 time-out (procedure fails to move to control channel
onward from phase 3 or phase 4 during V.34 reception)
Cause Remedy
• The line of the transmitting device broke in
phase 3 or phase 4, of signals of the transmitting
device cannot be detected.
• Prohibit the V.8/V.34 procedure of the callee
using bit 1 of SW28 of #1 SSSW.
Adjust the transmission level to between 0 and
-15 dBm.