Specifications
CHAPTER 4 SERVICE MODE
4-46
COPYRIGHT
©
1999 CANON INC. CANON SUPER G3 FAX BOARD-F1 REV.0 APR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
c. Line Test (LINE DETECT)
Press ‘LINE TEST’ on the FACULTY TEST Menu screen to start line mode and to bring up the
following screen.
Use this mode to execute testing on the sensors associated with the NCU and frequency counter.
(1) LINE DETECT 1
Press ‘LINE DETECT 1’ on the Line Test Menu screen to highlight and then the OK key to
bring up the following screen:
Use this function to check CI and FC from the line and the state (on/off) of hooking.
For CI, the applicable frequency is also indicated (0 with CI off, ‘0’; with CI on, its frequency).
<DETECT 1>
Report
Sssw Menu Num Ncu
Type
Genesis
Print Clear Test
<FACULTY> <LINE DETECT>
LINE DETECT 1
LINE DETECT 2
LINE DETECT 3
<READY>
Report
Sssw Menu Num Ncu
Type
Genesis
Print Clear Test
<FACULTY> <LINE DETECT>
C1 =OFF
CI FREQ =0Hz
HOOK =ON
FC =OFF