Specifications

COPYRIGHT
©
1999 CANON INC. CANON SUPER G3 FAX BOARD-F1 REV.0 MAY 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
4-15
CHAPTER 4 SERVICE MODE
#1 SSSW-SW07: closed area connection function setting
The closed area connection function is intended for communication with specific faxes only, and
is effective only if the other device is equipped with a closed area connection function.
Bit 6
Use it to enable/disable the closed area connection reception function.
If reception from specific faxes is wanted, select "Yes," and set the ID used by such faxes. To set the
ID, use the eight bits of SW08.
bit 7
Use it to enable/disabled the closed connection transmission function.
If transmission to specific faxes is wanted, select "Yes," and set the ID used by such faxes. To set the
ID, use the eight bits of SW08.
If the selected ID does not match the same ID as the other device, error code #039 will be indicated.
07
0
1
3
4
0
0
0
0
Do not change
Do not change
Transmit bits after bit 33 of DIS signal
Cut paper declaration by DIS signal
1
Yes
0
No
Yes No
2 0Do not change
5 0Do not change
6 0Closed area connection reception
7 0Closed area connection transmission
SW
No.
Bit
No.
Description
Bit setting
Default