Owner's Guide

3
3-20 Color Calibration
13. Click Read Strip.
The DTP41 pulls the measurement page through automatically.
14. Once the measurement page is read, Calibrator instructs you to insert and align the
page again for the next color. Repeat the measurement process for the magenta,
yellow, and black strips.
A check mark appears on the circle of the color just read, and the Status field indicates
that color was measured successfully.
The Previous and Next buttons on the Measurements window can be used to reverse
or advance to another step in the measurement sequence to repeat a measurement.
Status field indicates color
was measured successfully
Previous and Next buttons
let you advance or reverse
to repeat a measurement