Technical information

COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON CLC5000 REV.0 JAN. 2001
ERROR CODE
E-21
E405
Cause Pick-up motor (M1; faulty)
Pick-up motor clock sensor (S12; faulty)
Description
The number of pick-up motor clock pulses is below a specific value for 200
ms.
E407
Cause Pick-up motor (M6; faulty)
Tray position sensor (S25; faulty)
Description
The sensor state does not change even the tray ascent motor is driven for 2
sec or more.
E408
Cause Feeding motor (M8; faulty)
Feeding motor clock sensor (S22; faulty)
Description
The number of feeding motor clock pulses is below a specific value for 100
ms.
E411
Cause Registration sensor 1 (S3; faulty)
Skew sensor 1 (S4; faulty)
Manual feed registration sensor (S19; faulty)
Image leading edge sensor (S20; faulty)
Original sensor 1 (S7; faulty)
Description
The output of each sensor in the absence of paper is higher than a specific
value.