Technical information

COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON CLC5000 REV.0 JAN. 2001
ERROR CODE
E-19
E350
Cause ECO-ID PCB (faulty)
Description
The ECO-ID PCB is not mounted.
The connection between ECO-ID PCB and reader controller PCB is
faulty.
During the power switch has been turned ON, the communication between
ECO-ID PCB and the reader controller is not normal.
E351
Cause Image processor PCB (faulty)
Description
The communication within the image processor PCB is faulty.
E620
Cause IP-MAIN PCB (faulty)
IP-ED PCB (faulty)
Description
The communication between the IP-ED PCB and the IP-MAIN PCB is
interrupted for 5 sec or more.
E700
Cause DC controller PCB (faulty)
Reader unit controller PCB (faulty)
Power supply PCB (faulty)
Description
The communication between the DC controller PCB and the reader unit
controller PCB is disrupted for 5 sec or more.