ERROR CODE
E-17
E077
Cause The transfer belt waste toner motor is faulty; the connection between the
moor and the DC controller PCB is faulty; or the DC controller PCB is
faulty.
Description
0001 The error detection circuit on the DC controller PCB has detected
overcurrent in the transfer belt waste toner motor drive circuit.
E100
Cause • Laser unit (faulty)
• Laser driver PCB (faulty)
• Image processor PCB (faulty)
Description
xx01 At the start of potential control, the BD signal is not detected for 1
sec or more.
xx02 The operation ON current used to obtain optimum intensity is
larger than a specific value.
E110
Cause • Laser scanner drive system (overload)
• Laser scanner motor (M4; faulty)
• DC controller PCB (faulty)
Description
The rotation speed of the motor has deviated from a specific value for 0.1
sec or more.
E194
Cause • CCD unit for pattern reading (faulty)
• PCB for pattern reading (faulty)
• DC controller PCB (faulty)
In addition, a fault in the primary charging assembly or the transfer belt
may have prevented the formation of a pattern.
Description
xx01 The center of a pattern cannot be determined.
xx02 The center position (difference) in relation to the M pattern is 61 or
more in main scanning direction.
xx03
The center position (difference) in relation to the M pattern is 113 or
more for C and Bk and 141 or more for Y in sub scanning direction.
0001 After the shutter motor has started to rotate, the shutter open sensor
does not turn on after a specific period of time.
0002 After the shutter motor has started to rotate, the shutter closed sen-
sor does not turn on after a specific period of time.