Technical information
COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON CLC5000 REV.0 JAN. 2001
ERROR CODE
E-15
E062
Cause
Description
Drum Temperature Control Fault
xx=00: common error
xx=01: C
xx=02: M
xx=03: Y
xx=04: Bk
Cause • DC controller PCB (faulty)
• AC driver (faulty)
Description
xx01 The drum temperature is 57°C or more for 0.5 sec or more.
xx02 The drum temperature has dropped below 15°C or less after it has
reached a specific temperature.
Cause Drum thermistor (faulty)
Description
0010 The drum thermistor has an open circuit or a short circuit.
E072
Cause • Belt cleaner drive motor
• Transfer belt unit
• DC controller
Description
The sensor output does not change after a specific period of time (6 sec).
E073
Cause • Transfer drawer connector (fault)
• DC controller PCB (fault)
• Transfer belt edge sensor (fault)
Description
0001 The connect signal CONNECT of the transfer assembly frame goes
‘0’ when the front cover is closed.
0002 The transfer belt edge sensor 4 (PS20) and the transfer belt edge
sensor 1 (PS17) detected the belt at the same time.
0003 The transfer belt edge sensor 3 (PS19) and the transfer belt edge
sensor 2 (PS18) detected the belt at the same time.
0004 The transfer belt edge sensor 3 (PS19) and the transfer belt edge
sensor 4 (PS20) detected the belt at the same time.
0005 The transfer belt edge sensor 1 (PS17) and the transfer belt edge
sensor 2 (PS18) detected the belt at the same time.