Technical information

COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON CLC5000 REV.0 JAN. 2001
ERROR CODE
E-12
E061
Cause Primary charging assembly (faulty)
HVDC (faulty)
Description
xx11 The measurement of VD1 is 900 V or higher and, in addition, the
measurement of VD2 is 900 V or higher.
Cause Video controller PCB (faulty)
Laser unit (faulty)
Description
xx12 The measurement of VD1 is 200 V or lower and, in addition, the
measurement of VD2 is 600 V or lower.
xx13 The measurement of VD1 is 150 V or lower and, in addition, the
measurement of VD2 is 300 V or lower.
Cause Primary charging assembly (faulty)
HVDC (faulty)
Description
xx14 The measurement of VD1 is 150 V or lower and, in addition, the
measurement of VD2 is 150 v or lower.
Cause Potential measurement unit (faulty)
DC controller PCB (faulty)
Description
xx15 The measurement of VD1, VD2, VL1, or VL2 is 10 V or lower.
Cause Video controller PCB (faulty)
Laser unit (faulty)
Scanner (faulty)
Description
xx16 The difference between VD1 and VL1 measurements is 20 V or
less and, in addition, the measurement of VD1 is 200 V or more.
The difference between VD2 and VL2 measurements is 200 V or
less and, in addition, the VD2 measurement is 600 V or higher.
Cause Video controller PCB (faulty)
Laser intensity (poor adjustment)
Laser unit (faulty)
Description
xx17 The VL1 measurement is 200 V or higher and, in addition, the VL2
measurement is 400 V or higher.