Technical information
COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON CLC5000 REV.0 JAN. 2001
ERROR CODE
E-11
E050
Cause • Duplex paper jogging guide motor (M23; faulty)
• Duplex paper jogging guide home position sensor (PS29; faulty)
• DC controller PCB (faulty)
Description
0001 The duplexing unit stacking guide home position sensor (PS29)
does not turn ON within 4 sec after the duplex paper jogging guide
motor (M23) has turned ON.
0002 The duplex paper jogging guide home position sensor (PS29) re-
mains ON for 1 sec or more after the duplexing unit stacking guide
motor (M23) has turned ON.
E061
Cause
Description
Potential Control Fault
high-order 2 digits
xx=00: common error
xx=01: C
xx=02: M
xx=03: Y
xx=04: Bk
Cause • Potential measurement unit (faulty)
• DC controller PCB (faulty)
• Pre-exposure lamp (fault)
Description
xx01 The difference between VD1 measured during the 1st rotation and
VD1 measured during the 2nd rotation is 30 V or more.
xx02 The difference between VD2 measured during the 1st rotation and
VD2 measured during the 2nd rotation is 30 V or more.
xx03 The difference between VL1 measured during the 1st rotation and
VL1 measured during the 2nd rotation is 30 V or more.
xx04 The difference between VL2 measured during the 1st rotation and
VL2 measured during the 2nd rotation is 30 V or more.
Cause • Primary/Pre-primary charging assembly (faulty)
• HVDC (faulty)
• Pre-exposure lamp (faulty)
Description
xx10 The measurement of VD1 is 500 V or higher and, in addition, the
measurement of VD2 is 900 V or higher.