ERROR CODE
E-9
E020
Cause • Developer (deterioration)
• Developing cylinder (rotation failure)
• Toner density sensor (faulty)
• Developer (inside developing assembly; stirring fault)
• Toner level sensor (faulty)
Description
xxD0 The value of the toner supply time correction data based on
‘SGNL-C/M/Y’ is 141 or more for 20 copies or more during copy-
ing sequence.
xxE0 The value of the toner supply time correction data based on
‘SGNL-C/M/Y’ is -188 or less for 20 copies or more during copy-
ing sequence.
E023
Cause • Developing motor (faulty)
• DC controller PCB (faulty)
• Developing cylinder (rotation failure)
Description
0101 The rotation speed of the C developing motor (M18C) has deviated
from a specific value for 0.1 sec or more (PLL signal ‘0’).
0201 The rotation speed of the M developing assembly (M18M) has de-
viated from a specific value for 0.1 sec or more (PLL signal ‘0’).
0301 The rotation speed of the Y developing motor (M18Y) has deviated
from a specific value for 0.1 sec or more (PLL signal ‘0’).
0401 The rotation speed of the Bk developing motor (M18Bk) has devi-
ated from a specific speed for 0.1 sec or more (PLL signal ‘0’).
E030
Cause • Counter (open circuit)
• DC controller PCB (faulty)
Description
Check immediately before the counter turns ON and OFF.
(Normal if the counter drive signal is ‘0’ when the counter turns ON; nor-
mal if the counter drive signal is ‘1’ when the counter turns OFF.)
E032
Cause Data communication (error between Copy Data Controller-A1 and copier)
Description
After the copier has generated the copy start signal, count pulses have not
been detected by the data Controller-A1 within a specific period of time.