E020
Cause Developer (deterioration)
Developing cylinder (rotation failure)
Toner density sensor (faulty)
Developer (inside developing assembly; stirring fault)
Toner level sensor (faulty)
Description
xxD0 The value of the toner supply time correction data based on
‘SGNL-C/M/Y’ is 141 or more for 20 copies or more during copy-
ing sequence.
xxE0 The value of the toner supply time correction data based on
‘SGNL-C/M/Y’ is -188 or less for 20 copies or more during copy-
ing sequence.
E023
Cause Developing motor (faulty)
DC controller PCB (faulty)
Developing cylinder (rotation failure)
Description
0101 The rotation speed of the C developing motor (M18C) has deviated
from a specific value for 0.1 sec or more (PLL signal ‘0’).
0201 The rotation speed of the M developing assembly (M18M) has de-
viated from a specific value for 0.1 sec or more (PLL signal ‘0’).
0301 The rotation speed of the Y developing motor (M18Y) has deviated
from a specific value for 0.1 sec or more (PLL signal ‘0’).
0401 The rotation speed of the Bk developing motor (M18Bk) has devi-
ated from a specific speed for 0.1 sec or more (PLL signal ‘0’).
E030
Cause Counter (open circuit)
DC controller PCB (faulty)
Description
Check immediately before the counter turns ON and OFF.
(Normal if the counter drive signal is ‘0’ when the counter turns ON; nor-
mal if the counter drive signal is ‘1’ when the counter turns OFF.)
E032
Cause Data communication (error between Copy Data Controller-A1 and copier)
Description
After the copier has generated the copy start signal, count pulses have not