Technical information
COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON CLC5000 REV.0 JAN. 2001
ERROR CODE
E-8
E020
xxB1 When setting initial data, the average after sampling of the follow-
ing values is 859 or higher:
REF-C, REF-M, REF-Y
xxB2 When setting initial data, the average after sampling of the follow-
ing values is 255.
SIGG-C, SIGG-M, SIGG-Y
xxB5 When setting initial data, the average after sampling of the follow-
ing values is 777 or lower:
SGNL-C, SGNL-M, SGNL-Y
xxB6 When setting initial data, the average of the following values after
sampling is 205 or lower:
REF-C, REF-M, REF-Y
xxB7 When setting initial data, the average of the following values after
sampling is 0:
SIGG-C, SIGG-M, SIGG-Y
xxBA During copying sequence, the average of the following values after
sampling is 1013 or higher:
SGNL-C, SGNL-M, SGNL-Y
Cause • Developing assembly (deterioration)
• Developing cylinder (rotation failure)
• Developing assembly (locking failure)
• Toner density sensor (faulty)
• Developer (inside developing assembly; stirring fault)
• Toner level sensor (faulty)
Description
xxBB During copying sequence, the value of the following is 30% or
more higher than the initial setting:
REF-C, REF-M, REF-Y
xxBC During copying sequence, the average of the following values after
sampling is 306 or higher:
SGNL-C, SGNL-M, SGNL-Y
xxBD During copying sequence, the value of the following is 30% or
more lower than the initial setting:
REF-C, REF-M, REF-Y
xxBF When setting initial data, the values of the following cannot be set:
SIGG-C, SIGG-M, SIGG-Y
Cause • Toner sensor (faulty)
• Toner stirring screw (faulty)
Description
xxF1 The C/M/Y hopper error sensor has detected the absence of toner.
04F2 The Bk hopper error sensor has detected the absence of toner 10
times or more continuously.