Technical information
COPYRIGHT
©
2001 CANON INC. 2000 2000 2000 2000 CANON CLC5000 REV.0 JAN. 2001
ERROR CODE
E-5
E020
xx40 When setting initial data (upon installation, for example), the aver-
age value after sampling of the following values is 848 or higher:
SGNL-S-C, SGNL-S-M, SGNL-S-Y, SGNL-S-K; or,
the value of SGNL-S-K is 352 or higher.
xx41 When setting initial data (upon installation, for example), the aver-
age value after sampling of the following values is 848 or higher:
REF-S-C, REF-S-M, REF-S-Y, REF-S-K; or,
the value of REF-S-K is 544 or higher.
xx42 When setting initial data (upon installation, for example), the value
of the following is 255:
SIGG-S-C, SIGG-S-M, SIGG-S-Y, SIGG-S-K
xx43 When setting initial data (upon installation, for example), the gain
of the SALT reference signal for each color is 255.
xx45 When setting initial data (upon installation, for example), the aver-
age value after sampling of the following values is 512 or higher:
SGNL-S-C, SGNL-S-M, SGNL-S-Y; or,
the value of SGNL-S-K is 144 or lower.
xx46 When setting initial data (upon installation, for example), the aver-
age value after sampling of the following values is 336 or less:
REF-S-C, REF-S-M, REF-S-Y; or,
the value of REF-S-K is 464 or lower.
xx47 When setting initial data (upon installation, for example), the aver-
age value after sampling of the following values is 0:
SIGG-S-C, SIGG-S-M, SIGG-S-Y, SIGG-S-K.
xx48
When setting initial data (upon installation, for example), the average
gain after sampling of the SALT reference signal for each color is 0.
Cause Back-up data (DC controller PCB; error)
Be sure to execute RAM clear, and enter the value recorded on the service
label.
(Or, initial settings may be missing.)
Description
xx4A During copying sequence, the average value after sampling of the
following values is 848 or higher:
SGNL-S-C, SGNL-S-M, SGNL-S-Y; or,
the value of SGNL-S-K is 445 or higher.
xx4B During copying sequence, the average value after sampling of the
following values is 848 or higher:
SGNL-S-C, SGNL-S-M, SGNL-S-Y; or,
the value of REF-S-K is 544 or higher.
xx4C During copying sequence, the average value after sampling of the
following values is 512 or lower:
SGNL-S-C, SGNL-S-M, SGNL-S-Y; or,
the value of SGNL-S-K is 102 or lower.