SERVICE MODE
S-124
T-WEB
*1
Changes the frequency at which the transfer belt cleaning web turns on.
Settings range
1~5
(Standard: 3)
TBLT-POS
*1
Changes the stop position of the transfer belt.
Settings range
–2~2
Unit: 2 mm
(Standard: 0)
F-WEB-MD
Changes the ON/OFF sequence of the web solenoid when the fixing web
solenoid is turned on.
At present, the setting is always ‘1’.
Settings Standard: 1
F-WEB
*1
Changes the frequency at which the fixing web solenoid turns on.
Settings range
1~255
(Standard: 8)
PSTCL-ON
Enabling or disabling the charging mechanism after display cleaning turn it
on or off as needed if memory of the edge of a sheet occurs in a low-tem-
perature environment or cyan or black dots occur in the images.
Setting 0: Normal
1: All environment ON
<M> <S> <R> <P> <F>
REG-NEXT
0
DISP
ADJUST
FUNC
F-WEB-MD
COUNTER
OPTION
F-WEB
TEST
P-OPT
READY READY
0
PSTCL-ON
0
0
T-WEB
TBLT-POS
00
AUTO-REG
0
<P-OPT (Making settings Retated to the Printer unit)>