Technical information
COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-106
<F-MISCp (printer-related operation/inspection)>
<M> <S> <R> <P> <F>
<M> <S> <R> <P> <F>
DISP
IO IO-ON
ADJUST
COUNTER
FUNC
OPTION
TEST
SHV SHV-ON MTR MTR-ON DRM-ROT
1
1
1
1
FAN FAN-ON
F-MISCp READY
1/2
FUNC
DISP
ADJUST
COUNTER
OPTION
TEST
E075-RLS SHUT-OFF
F-MISCp
2/2
F00-400-23
IO
Use it to select the type of IO (input/output) check.
See the details section.
IO-ON
Use it to start an IO (input/output) check.
SHV
Use it to select the type of check on the high-voltage output.
Enter a number on the keypad, and press the OK key.
See the details section in SHV.
SHV-ON
Use it to start a check on the high-voltage output.
Press the Stop key to stop operation.
MTR
Use it to select the type of check on the motor.
Enter a number on the keypad, and press the OK key.
See the details section in MTR.