Technical information
COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-101
<FUSER (fixing assembly-related adjustment)>
<M> <S> <R> <P> <F>
DISP
NIP-CHK
ADJUST
COUNTER
FUNC
OPTION
TEST
E000-RLS
E005-RLS
FUSER READY
UPPER-CR
LOWER-CR
F00-400-19
NIP-CHK
Measures the fixing assembly nip.
Paper is stopped once at the point of fixing and then delivered.
Sine the operation uses cassette 1 as the source of paper, ‘NO PAPER’ will
be indicated over ‘P’ if no paper exists in cassette 1. The notation changes
to ‘READY’ when paper is supplied.
Remarks Press NIP-CHK to execute.
The notation over ‘P’ changes from READY to SERVICE and then to
READY to end the execution.
E000-RLS
Clears E000.
Be sure to turn off and then on the power switch after execution.
Remarks The notation over ‘P’ changes from ERROR to BUSY and then to ERROR.
Turn off and on the power switch to clear.
E005-RLS
Clears E005.
Be sure to turn off and then on the power switch after execution.
Remarks The notation over ‘P’ changes from ERROR to BUSY and then to ERROR.
Turn off and on the power switch to clear.
UPPER-CR
Use it to adjust the fixing temperature value (upper roller).
If you have replaced the fixing assembly, enter the value recorded on the
label attached to the fixing assembly.
Thereafter, be sure to turn off and then on the power switch.