Technical information
COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-90
<CCD (CCD-related adjustment)>
<M> <S> <R> <P> <F>
<M> <S> <R> <P> <F>
FUNC
FUNC
DISP
ADJUST
COUNTER
OPTION
TEST
GAIN-UP BLUE
BLUE
xxxx
xxxx
GREEN
GREEN
xxxx
xxxx
RED
RED
xxxx
xxxx
DISP AUTO-ADJ
ADJUST
COUNTER
OFST-E
OPTION
TEST
GAIN-O
LAMP
GAIN-E
BLUE
xxxx
BLUE
xxxx
xxxx
AP-TYPE
xxxx
GREEN
xxxx
GREEN
xxxx
RED
xxxx
OFST-O BLUE
xxxx
GREEN
xxxx
RED
xxxx
RED
xxxx
CCD READY
1/2
CCD READY
2/2
CCD-MODE
0
CCD-DISP
0
F00-400-11
AUTO-ADJ
Use it to specify the start of auto adjustment.The bar code data recorded on
the standard white plate is read, and offset adjustment, intensity adjustment
for the scanning lamp, and gain adjustment are executed in sequence.
The display changes as follows: <R>RADY → Bar code → OeAdj → Offdj
→ LampAdj → GainAdj → OeAdj → InitBAdj → Gz-bar.
Remarks Adjustments are made so that the value of point A is identical to the setting
obtained from the bar code data recorded on the standard white plate.
LAMP
Use it to indicate the level adjustment value of the scanning lamp.
CCD-MODE
Use it to indicate whether the mode selected in user mode is normal mode
or precious metal mode.
0: normal mode
1: precious metal mode