SERVICE MODE
S-88
F00-400-09
Entering Backup Data
If you have executed ‘RAM-CLR’ for the DC controller PCB, use this screen to enter the
data recorded on the service label.
SGNL-S-C/M/Y/K
Use it to enter the value of the SALT signal.
REF-S-C/M/Y/K
Use it to enter the value of the SALT reference signal.
SGNL-D-C/M/Y/K
Use it to enter the value of the signal representing the intensity of light re-
flected by the photosensitive drum.
SIGG-S-C/M/Y/K
Use it to enter the value of the gain for the SALT signal.
PT-OFST-K
Use it to enter the adjustment value of the density pattern for SALT.
PUDT-U/L
Use it to enter the adjustment value for pick-up timing adjustment (P-UP-
TMG).
<M> <S> <R> <P> <F>
FUNC
DISP
ADJUST
COUNTER
OPTION
TEST
REF-S-M
SIGG-S-M
xxxx
xxxx
xxxx
PUDT-L
xxxx
SIGG-S-K
xxxx
PTOFST-K
xxxx
REF-S-K
xxxx
SGNL-S-M
xxxx
SGNL-S-K
xxxx
SGNL-S-Y
xxxx
REF-S-Y
xxxx
SIGG-S-Y
xxxx
PUDT-U
xxxx
SGNL-D-Y
xxxx
SGNL-D-M
REF-S-C
SIGG-S-C
xxxx
xxxx
xxxx
SGNL-S-C
xxxx
SGNL-D-C
xxxx
SGNL-D-K
DC-CON READY4/5