SERVICE MODE
S-86
F00-400-07
Entering Backup Data
If you have executed ‘RAM-CLR’ for the DC controller PCB, use this screen to enter the
data recorded on the service label.
UP-A4R
Enters the adjustment value for paper width detection reference point 1 for
cassette 1.
UP-STMR
Enters the adjustment value for paper width detection reference point 2 for
cassette 1.
LOW-A4R
Enters the adjustment value for paper width detection reference point 1 for
cassette 2.
LOW-STMR
Enters the adjustment value for paper width detection reference point 2 for
cassette 2.
MF-A4R
Enters the adjustment value for paper width detection reference point 1 for
the multifeeder.
MF-A6R
Enters the adjustment value for paper width detection reference point 2 for
the multifeeder.
MF-A4
Enters the adjustment value for paper width detection reference point 3 for
the multifeeder.
<M> <S> <R> <P> <F>
FUNC
xxxx
xxxx
xxxx
xxxx
xxxx
xxxx xxxx
DISP
ADJUST
COUNTER
OPTION
TEST
UP-A4R UP-STMR
LOW-STMR
MF-A6R MF-A4
LOW-A4R
MF-A4R
DC-CON