Technical information
COPYRIGHT
©
2001 CANON INC.
2000 2000 2000 2000
CANON CLC5000 REV.0 JAN. 2001
SERVICE MODE
S-82
F00-400-03
<M> <S> <R> <P> <F>
xxx
xxx
xxx
FUNC
DISP
ADJUST
COUNTER
OPTION
TEST
xxx
xxx
xxx
SGNL-Y
REF-Y
SIGG-Y
SGNL-M
REF-M
SIGG-M
xxx
xxx
xxx
SGNL-C
REF-C
SIGG-C
INSTALL
3/4
SGNL-C/M/Y
Indicates the value of the toner density signal when INIT is executed as
ATR control.
Be sure to record the reading on the label.
Remarks For SGNL-C, SGNL-M, and SGNL-Y, normally, 818 ±41.
REF-C/M/Y
Indicates the value of the toner density reference signal when INIT is ex-
ecuted as ATR control.
Be sure to record the reading on the label.
SIGG-C/M/Y
Indicates the gain value (gain value used to set SGNL-C/SGNL-M/SGNL-
Y to 818) for the toner density signal during ATR control.
Be sure to record the reading on the label.