SERVICE MODE
S-81
NLSET-K
Use it to suppress fogging of Bk, if noted in a low-humidity environment,
as follows:
1. In the environment in question, check to make sure that the moisture con-
tent is 5 g (indicated as ‘500 g’ on the screen) or less.
2. Replace the Bk developer. (See the descriptions of ‘replacing the devel-
oper’ in chapter 2. CLC1000 Service Handbook however, do not execute
auto gradation correction as yet.)
3. Execute ‘FUNC>INSTALL (2nd page)>NLSET-K’ in service mode.
(about 1 min)
4. Check to make sure that ‘PASCAL’ in ‘ADJUST>PASCAL’ in service
mode is ‘1’.
5. Execute auto gradation correction in user mode.
REG-APER
Executes auto correction of the read-in coordinates of the image position
correction pattern.
RECV-C/M/Y/K
Rotates the cylinder of the developing assembly to draw developer out of
the developing assembly of the specified color.
• Be sure to place the developer collecting container under the developer
before opening of the developer supply mouth.
This mode is NOT to be executed at time of installation.
RECV-4
Rotates the cylinders of the developing assemblies to draw the developers
out of the developing assemblies for four colors.
WINCLR-C/M/Y/K
Use it to read in the initial value of the window soiling correction coeffi-
cient of a specific color.
WINCLR-4
Use it to read in the initial value of the window soiling correction coeffi-
cient of the four colors.